An unexpected rise in an evaporator effect’s shell-side temperature can indicate reduced heat transfer. In multi-effect evaporators, this may also raise operating temperatures in other effects and reduce overall performance.
Compare current operating temperatures with the unit’s normal temperature profile. A larger-than-normal temperature difference between the heating-vapor side and the product boiling side in a particular effect is an indication of reduced performance.
Areas to Inspect
Condensate removal. Confirm condensate can drain freely from the effect in question. Flooded condensate on the shell side can block venting and limit heat transfer. Check for backed-up lines, closed or partially closed valves, blocked orifices, or condensate entering venting lines.
Non-condensable gas venting. Verify that shell vents are open and unobstructed. Inspect vent lines. A simple blow-through check can help identify blockages. If venting capacity appears insufficient, a larger vent orifice size may be needed.
Tube cleanliness. Inspect heat-transfer tubes for product buildup, plugging, or other evidence that the cleaning cycle is not removing deposits effectively. Review cleaning conditions, including flow, chemistry, concentration, temperature, and cycle duration against best practices.
Product foaming. Inspect for foam using available sight glasses during operation. Persistent foam can block vapor flows and reduce heat transfer, ultimately affecting temperatures. If foaming is present, inspect associated pumps, gaskets, and mechanical seals for air ingress or leakage.
Here are some additional best practices for troubleshooting:
- Confirm that operating data is accurate.
- Inspect for vacuum leaks, verify temperature and pressure instrumentation, and look for vapor-flow restrictions or product overflow between passes.
- When tube fouling recurs despite cleaning, investigate liquid distribution rather than treating deposits as purely a cleaning issue.
- If the cause remains unclear, a formal evaporator assessment can help identify the source of the performance loss and determine corrective action.
Operating Practices
Document temperatures, pressures, condensate levels, cleaning results, and visual observations before making adjustments. This record helps identify whether the issue is isolated to one effect or reflects a broader issue. If abnormal temperatures persist after these checks, consult a qualified engineer before changing control settings or hardware.
If you need assistance with troubleshooting and/or correcting conditions in your evaporator system, contact us. Call 410-822-6900 or problem.solved@caloris.com.